CVE-2017-10608

SRX series: Junos OS: SRX series using IPv6 Sun/MS-RPC ALGs may experience flowd crash on processing packets.

Description

Any Juniper Networks SRX series device with one or more ALGs enabled may experience a flowd crash when traffic is processed by the Sun/MS-RPC ALGs. This vulnerability in the Sun/MS-RPC ALG services component of Junos OS allows an attacker to cause a repeated denial of service against the target. Repeated traffic in a cluster may cause repeated flip-flop failure operations or full failure to the flowd daemon halting traffic on all nodes. Only IPv6 traffic is affected by this issue. IPv4 traffic is unaffected. This issues is not seen with to-host traffic. This issue has no relation with HA services themselves, only the ALG service. No other Juniper Networks products or platforms are affected by this issue. Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D55 on SRX; 12.1X47 prior to 12.1X47-D45 on SRX; 12.3X48 prior to 12.3X48-D32, 12.3X48-D35 on SRX; 15.1X49 prior to 15.1X49-D60 on SRX.

Remediation

Workaround:

  • Disable Sun/MS-RPC ALGs on the SRX Series device. Disable IPv6 on the device. example: deactivate interfaces xe-0/0/0 unit 0 family inet6 address 2000::254/64 Filtering incoming IPv6, or Sun/MS-RPC from the device is also an option. example: set interfaces xe-0/0/0 unit 0 family inet6 filter input TEST ==> apply to interface set firewall family inet6 filter TEST term t1 from destination-port 135 set firewall family inet6 filter TEST term t1 then discard

Category

7.5
CVSS
Severity: High
CVSS 3.0 •
CVSS 2.0 •
EPSS 0.39%
Vendor Advisory juniper.net
Affected: Juniper Networks Junos OS
Published at:
Updated at:

References

Link Tags
https://kb.juniper.net/JSA10811 vendor advisory

Frequently Asked Questions

What is the severity of CVE-2017-10608?
CVE-2017-10608 has been scored as a high severity vulnerability.
How to fix CVE-2017-10608?
As a workaround for remediating CVE-2017-10608: Disable Sun/MS-RPC ALGs on the SRX Series device. Disable IPv6 on the device. example: deactivate interfaces xe-0/0/0 unit 0 family inet6 address 2000::254/64 Filtering incoming IPv6, or Sun/MS-RPC from the device is also an option. example: set interfaces xe-0/0/0 unit 0 family inet6 filter input TEST ==> apply to interface set firewall family inet6 filter TEST term t1 from destination-port 135 set firewall family inet6 filter TEST term t1 then discard
Is CVE-2017-10608 being actively exploited in the wild?
As for now, there are no information to confirm that CVE-2017-10608 is being actively exploited. According to its EPSS score, there is a ~0% probability that this vulnerability will be exploited by malicious actors in the next 30 days.
What software or system is affected by CVE-2017-10608?
CVE-2017-10608 affects Juniper Networks Junos OS.
This platform uses data from the NIST NVD, MITRE CVE, MITRE CWE, First.org and CISA KEV but is not endorsed or certified by these entities. CVE is a registred trademark of the MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. CWE is a registred trademark of the MITRE Corporation and the authoritative source of CWE content is MITRE's CWE web site.