CVE-2019-18336

Description

A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC TDC CP51M1 (All versions < V1.1.8), SIMATIC TDC CPU555 (All versions < V1.1.1), SINUMERIK 840D sl (All versions < V4.8.6), SINUMERIK 840D sl (All versions < V4.94). Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitation requires an attacker to have network access to port 102/tcp, with no authentication. No user interation is required. At the time of advisory publication no public exploitation of this security vulnerability was known.

Category

7.5
CVSS
Severity: High
CVSS 3.1 •
CVSS 2.0 •
EPSS 0.25%
Vendor Advisory siemens.com
Affected: Siemens AG SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)
Affected: Siemens AG SIMATIC TDC CP51M1
Affected: Siemens AG SIMATIC TDC CPU555
Affected: Siemens AG SINUMERIK 840D sl
Affected: Siemens AG SINUMERIK 840D sl
Published at:
Updated at:

References

Frequently Asked Questions

What is the severity of CVE-2019-18336?
CVE-2019-18336 has been scored as a high severity vulnerability.
How to fix CVE-2019-18336?
To fix CVE-2019-18336, make sure you are using an up-to-date version of the affected component(s) by checking the vendor release notes. As for now, there are no other specific guidelines available.
Is CVE-2019-18336 being actively exploited in the wild?
As for now, there are no information to confirm that CVE-2019-18336 is being actively exploited. According to its EPSS score, there is a ~0% probability that this vulnerability will be exploited by malicious actors in the next 30 days.
What software or system is affected by CVE-2019-18336?
CVE-2019-18336 affects Siemens AG SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants), Siemens AG SIMATIC TDC CP51M1, Siemens AG SIMATIC TDC CPU555, Siemens AG SINUMERIK 840D sl, Siemens AG SINUMERIK 840D sl.
This platform uses data from the NIST NVD, MITRE CVE, MITRE CWE, First.org and CISA KEV but is not endorsed or certified by these entities. CVE is a registred trademark of the MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. CWE is a registred trademark of the MITRE Corporation and the authoritative source of CWE content is MITRE's CWE web site.