CVE-2019-6577

Description

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify particular parts of the device configuration via SNMP. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires system privileges and user interaction. An attacker could use the vulnerability to compromise confidentiality and the integrity of the affected system. At the stage of publishing this security advisory no public exploitation is known.

Categories

5.4
CVSS
Severity: Medium
CVSS 3.0 •
CVSS 2.0 •
EPSS 0.38%
Vendor Advisory siemens.com
Affected: Siemens AG SIMATIC HMI Comfort Panels 4" - 22"
Affected: Siemens AG SIMATIC HMI Comfort Outdoor Panels 7" & 15"
Affected: Siemens AG SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F
Affected: Siemens AG SIMATIC WinCC Runtime Advanced
Affected: Siemens AG SIMATIC WinCC Runtime Professional
Affected: Siemens AG SIMATIC WinCC (TIA Portal)
Affected: Siemens AG SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)
Published at:
Updated at:

References

Frequently Asked Questions

What is the severity of CVE-2019-6577?
CVE-2019-6577 has been scored as a medium severity vulnerability.
How to fix CVE-2019-6577?
To fix CVE-2019-6577, make sure you are using an up-to-date version of the affected component(s) by checking the vendor release notes. As for now, there are no other specific guidelines available.
Is CVE-2019-6577 being actively exploited in the wild?
As for now, there are no information to confirm that CVE-2019-6577 is being actively exploited. According to its EPSS score, there is a ~0% probability that this vulnerability will be exploited by malicious actors in the next 30 days.
What software or system is affected by CVE-2019-6577?
CVE-2019-6577 affects Siemens AG SIMATIC HMI Comfort Panels 4" - 22", Siemens AG SIMATIC HMI Comfort Outdoor Panels 7" & 15", Siemens AG SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, Siemens AG SIMATIC WinCC Runtime Advanced, Siemens AG SIMATIC WinCC Runtime Professional, Siemens AG SIMATIC WinCC (TIA Portal), Siemens AG SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel).
This platform uses data from the NIST NVD, MITRE CVE, MITRE CWE, First.org and CISA KEV but is not endorsed or certified by these entities. CVE is a registred trademark of the MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. CWE is a registred trademark of the MITRE Corporation and the authoritative source of CWE content is MITRE's CWE web site.