The Bluetooth Low Energy Secure Manager Protocol (SMP) implementation in Texas Instruments SimpleLink SIMPLELINK-CC2640R2-SDK through 2.2.3 allows the Diffie-Hellman check during the Secure Connection pairing to be skipped if the Link Layer encryption setup is performed earlier. An attacker in radio range can achieve arbitrary read/write access to protected GATT service data, cause a denial of service, or possibly control a device's function by establishing an encrypted session with an unauthenticated Long Term Key (LTK).
The product does not verify, or incorrectly verifies, the cryptographic signature for data.
Link | Tags |
---|---|
http://www.ti.com/tool/BLE-STACK | vendor advisory |
https://asset-group.github.io/disclosures/sweyntooth/ | third party advisory |
https://asset-group.github.io/cves.html | third party advisory |