CVE-2020-7581

Description

A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges.

Category

6.7
CVSS
Severity: Medium
CVSS 3.1 •
CVSS 2.0 •
EPSS 0.05%
Vendor Advisory siemens.com
Affected: Siemens Opcenter Execution Discrete
Affected: Siemens Opcenter Execution Foundation
Affected: Siemens Opcenter Execution Process
Affected: Siemens Opcenter Intelligence
Affected: Siemens Opcenter Quality
Affected: Siemens Opcenter RD&L
Affected: Siemens SIMATIC Notifier Server for Windows
Affected: Siemens SIMATIC PCS neo
Affected: Siemens SIMATIC STEP 7 (TIA Portal) V15
Affected: Siemens SIMATIC STEP 7 (TIA Portal) V16
Affected: Siemens SIMOCODE ES V15.1
Affected: Siemens SIMOCODE ES V16
Affected: Siemens Soft Starter ES V15.1
Affected: Siemens Soft Starter ES V16
Published at:
Updated at:

References

Frequently Asked Questions

What is the severity of CVE-2020-7581?
CVE-2020-7581 has been scored as a medium severity vulnerability.
How to fix CVE-2020-7581?
To fix CVE-2020-7581, make sure you are using an up-to-date version of the affected component(s) by checking the vendor release notes. As for now, there are no other specific guidelines available.
Is CVE-2020-7581 being actively exploited in the wild?
As for now, there are no information to confirm that CVE-2020-7581 is being actively exploited. According to its EPSS score, there is a ~0% probability that this vulnerability will be exploited by malicious actors in the next 30 days.
What software or system is affected by CVE-2020-7581?
CVE-2020-7581 affects Siemens Opcenter Execution Discrete, Siemens Opcenter Execution Foundation, Siemens Opcenter Execution Process, Siemens Opcenter Intelligence, Siemens Opcenter Quality, Siemens Opcenter RD&L, Siemens SIMATIC Notifier Server for Windows, Siemens SIMATIC PCS neo, Siemens SIMATIC STEP 7 (TIA Portal) V15, Siemens SIMATIC STEP 7 (TIA Portal) V16, Siemens SIMOCODE ES V15.1, Siemens SIMOCODE ES V16, Siemens Soft Starter ES V15.1, Siemens Soft Starter ES V16.
This platform uses data from the NIST NVD, MITRE CVE, MITRE CWE, First.org and CISA KEV but is not endorsed or certified by these entities. CVE is a registred trademark of the MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. CWE is a registred trademark of the MITRE Corporation and the authoritative source of CWE content is MITRE's CWE web site.