An instance of improper neutralization of special elements in the sniffer module of FortiSandbox before 3.2.2 may allow an authenticated administrator to execute commands on the underlying system's shell via altering the content of its configuration file.
The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component.
Link | Tags |
---|---|
https://fortiguard.com/advisory/FG-IR-21-005 | vendor advisory |