CVE-2021-27196

Specially Crafted IEC 61850 Protocol Sequence Vulnerability

Description

Improper Input Validation vulnerability in Hitachi ABB Power Grids Relion 670 Series, Relion 670/650 Series, Relion 670/650/SAM600-IO, Relion 650, REB500, RTU500 Series, FOX615 (TEGO1), MSM, GMS600, PWC600 allows an attacker with access to the IEC 61850 network with knowledge of how to reproduce the attack, as well as the IP addresses of the different IEC 61850 access points (of IEDs/products), to force the device to reboot, which renders the device inoperable for approximately 60 seconds. This vulnerability affects only products with IEC 61850 interfaces. This issue affects: Hitachi ABB Power Grids Relion 670 Series 1.1; 1.2.3 versions prior to 1.2.3.20; 2.0 versions prior to 2.0.0.13; 2.1; 2.2.2 versions prior to 2.2.2.3; 2.2.3 versions prior to 2.2.3.2. Hitachi ABB Power Grids Relion 670/650 Series 2.2.0 versions prior to 2.2.0.13. Hitachi ABB Power Grids Relion 670/650/SAM600-IO 2.2.1 versions prior to 2.2.1.6. Hitachi ABB Power Grids Relion 650 1.1; 1.2; 1.3 versions prior to 1.3.0.7. Hitachi ABB Power Grids REB500 7.3; 7.4; 7.5; 7.6; 8.2; 8.3. Hitachi ABB Power Grids RTU500 Series 7.x version 7.x and prior versions; 8.x version 8.x and prior versions; 9.x version 9.x and prior versions; 10.x version 10.x and prior versions; 11.x version 11.x and prior versions; 12.x version 12.x and prior versions. Hitachi ABB Power Grids FOX615 (TEGO1) R1D02 version R1D02 and prior versions. Hitachi ABB Power Grids MSM 2.1.0 versions prior to 2.1.0. Hitachi ABB Power Grids GMS600 1.3.0 version 1.3.0 and prior versions. Hitachi ABB Power Grids PWC600 1.0 versions prior to 1.0.1.4; 1.1 versions prior to 1.1.0.1.

Remediation

Solution:

  • Refer to the cybersecurity advisories at https://www.hitachiabb-powergrids.com/offering/solutions/cybersecurity/alerts-and-notifications

Category

7.5
CVSS
Severity: High
CVSS 3.1 •
CVSS 2.0 •
EPSS 1.04% Top 25%
Vendor Advisory abb.com Vendor Advisory abb.com Vendor Advisory abb.com Vendor Advisory abb.com Vendor Advisory abb.com Vendor Advisory abb.com Vendor Advisory abb.com
Affected: n/a n/a
Published at:
Updated at:

References

Frequently Asked Questions

What is the severity of CVE-2021-27196?
CVE-2021-27196 has been scored as a high severity vulnerability.
How to fix CVE-2021-27196?
To fix CVE-2021-27196: Refer to the cybersecurity advisories at https://www.hitachiabb-powergrids.com/offering/solutions/cybersecurity/alerts-and-notifications
Is CVE-2021-27196 being actively exploited in the wild?
It is possible that CVE-2021-27196 is being exploited or will be exploited in a near future based on public information. According to its EPSS score, there is a ~1% probability that this vulnerability will be exploited by malicious actors in the next 30 days.
This platform uses data from the NIST NVD, MITRE CVE, MITRE CWE, First.org and CISA KEV but is not endorsed or certified by these entities. CVE is a registred trademark of the MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. CWE is a registred trademark of the MITRE Corporation and the authoritative source of CWE content is MITRE's CWE web site.
© 2025 Under My Watch. All Rights Reserved.