CVE-2021-37185

Description

A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations.

Category

7.5
CVSS
Severity: High
CVSS 3.1 •
CVSS 2.0 •
EPSS 1.43% Top 25%
Vendor Advisory siemens.com
Affected: Siemens SIMATIC Drive Controller family
Affected: Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)
Affected: Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants)
Affected: Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)
Affected: Siemens SIMATIC S7-1500 Software Controller
Affected: Siemens SIMATIC S7-PLCSIM Advanced
Affected: Siemens SIPLUS TIM 1531 IRC
Affected: Siemens TIM 1531 IRC
Published at:
Updated at:

References

Frequently Asked Questions

What is the severity of CVE-2021-37185?
CVE-2021-37185 has been scored as a high severity vulnerability.
How to fix CVE-2021-37185?
To fix CVE-2021-37185, make sure you are using an up-to-date version of the affected component(s) by checking the vendor release notes. As for now, there are no other specific guidelines available.
Is CVE-2021-37185 being actively exploited in the wild?
It is possible that CVE-2021-37185 is being exploited or will be exploited in a near future based on public information. According to its EPSS score, there is a ~1% probability that this vulnerability will be exploited by malicious actors in the next 30 days.
What software or system is affected by CVE-2021-37185?
CVE-2021-37185 affects Siemens SIMATIC Drive Controller family, Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants), Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants), Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), Siemens SIMATIC S7-1500 Software Controller, Siemens SIMATIC S7-PLCSIM Advanced, Siemens SIPLUS TIM 1531 IRC, Siemens TIM 1531 IRC.
This platform uses data from the NIST NVD, MITRE CVE, MITRE CWE, First.org and CISA KEV but is not endorsed or certified by these entities. CVE is a registred trademark of the MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. CWE is a registred trademark of the MITRE Corporation and the authoritative source of CWE content is MITRE's CWE web site.