A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). An attacker in machine-in-the-middle could obtain plaintext secret values by observing length differences during a series of guesses in which a string in an HTTP request URL potentially matches an unknown string in an HTTP response body, aka a "BREACH" attack.
The product behaves differently or sends different responses under different circumstances in a way that is observable to an unauthorized actor, which exposes security-relevant information about the state of the product, such as whether a particular operation was successful or not.
Link | Tags |
---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf | patch vendor advisory |
https://cert-portal.siemens.com/productcert/html/ssa-484086.html |