CVE-2022-42784

Description

A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions >= V8.3), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions >= V8.3), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions >= V8.3), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions >= V8.3), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions >= V8.3), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions >= V8.3), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions >= V8.3), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions >= V8.3), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions >= V8.3). Affected devices are vulnerable to an electromagnetic fault injection. This could allow an attacker to dump and debug the firmware, including the manipulation of memory. Further actions could allow to inject public keys of custom created key pairs which are then signed by the product CA. The generation of a custom certificate allows communication with, and impersonation of, any device of the same version.

Category

7.6
CVSS
Severity: High
CVSS 3.1 •
EPSS 0.10%
Vendor Advisory siemens.com
Affected: Siemens LOGO! 12/24RCE
Affected: Siemens LOGO! 12/24RCEo
Affected: Siemens LOGO! 230RCE
Affected: Siemens LOGO! 230RCEo
Affected: Siemens LOGO! 24CE
Affected: Siemens LOGO! 24CEo
Affected: Siemens LOGO! 24RCE
Affected: Siemens LOGO! 24RCEo
Affected: Siemens SIPLUS LOGO! 12/24RCE
Affected: Siemens SIPLUS LOGO! 12/24RCEo
Affected: Siemens SIPLUS LOGO! 230RCE
Affected: Siemens SIPLUS LOGO! 230RCEo
Affected: Siemens SIPLUS LOGO! 24CE
Affected: Siemens SIPLUS LOGO! 24CEo
Affected: Siemens SIPLUS LOGO! 24RCE
Affected: Siemens SIPLUS LOGO! 24RCEo
Published at:
Updated at:

References

Frequently Asked Questions

What is the severity of CVE-2022-42784?
CVE-2022-42784 has been scored as a high severity vulnerability.
How to fix CVE-2022-42784?
To fix CVE-2022-42784, make sure you are using an up-to-date version of the affected component(s) by checking the vendor release notes. As for now, there are no other specific guidelines available.
Is CVE-2022-42784 being actively exploited in the wild?
As for now, there are no information to confirm that CVE-2022-42784 is being actively exploited. According to its EPSS score, there is a ~0% probability that this vulnerability will be exploited by malicious actors in the next 30 days.
What software or system is affected by CVE-2022-42784?
CVE-2022-42784 affects Siemens LOGO! 12/24RCE, Siemens LOGO! 12/24RCEo, Siemens LOGO! 230RCE, Siemens LOGO! 230RCEo, Siemens LOGO! 24CE, Siemens LOGO! 24CEo, Siemens LOGO! 24RCE, Siemens LOGO! 24RCEo, Siemens SIPLUS LOGO! 12/24RCE, Siemens SIPLUS LOGO! 12/24RCEo, Siemens SIPLUS LOGO! 230RCE, Siemens SIPLUS LOGO! 230RCEo, Siemens SIPLUS LOGO! 24CE, Siemens SIPLUS LOGO! 24CEo, Siemens SIPLUS LOGO! 24RCE, Siemens SIPLUS LOGO! 24RCEo.
This platform uses data from the NIST NVD, MITRE CVE, MITRE CWE, First.org and CISA KEV but is not endorsed or certified by these entities. CVE is a registred trademark of the MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. CWE is a registred trademark of the MITRE Corporation and the authoritative source of CWE content is MITRE's CWE web site.