CVE-2023-38071

Description

A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20824)

Categories

7.8
CVSS
Severity: High
CVSS 3.1 •
EPSS 0.07%
Vendor Advisory siemens.com Vendor Advisory siemens.com
Affected: Siemens JT2Go
Affected: Siemens Teamcenter Visualization V13.3
Affected: Siemens Teamcenter Visualization V14.0
Affected: Siemens Teamcenter Visualization V14.1
Affected: Siemens Teamcenter Visualization V14.2
Affected: Siemens Teamcenter Visualization V14.3
Affected: Siemens Tecnomatix Plant Simulation V2201
Affected: Siemens Tecnomatix Plant Simulation V2302
Published at:
Updated at:

References

Frequently Asked Questions

What is the severity of CVE-2023-38071?
CVE-2023-38071 has been scored as a high severity vulnerability.
How to fix CVE-2023-38071?
To fix CVE-2023-38071, make sure you are using an up-to-date version of the affected component(s) by checking the vendor release notes. As for now, there are no other specific guidelines available.
Is CVE-2023-38071 being actively exploited in the wild?
As for now, there are no information to confirm that CVE-2023-38071 is being actively exploited. According to its EPSS score, there is a ~0% probability that this vulnerability will be exploited by malicious actors in the next 30 days.
What software or system is affected by CVE-2023-38071?
CVE-2023-38071 affects Siemens JT2Go, Siemens Teamcenter Visualization V13.3, Siemens Teamcenter Visualization V14.0, Siemens Teamcenter Visualization V14.1, Siemens Teamcenter Visualization V14.2, Siemens Teamcenter Visualization V14.3, Siemens Tecnomatix Plant Simulation V2201, Siemens Tecnomatix Plant Simulation V2302.
This platform uses data from the NIST NVD, MITRE CVE, MITRE CWE, First.org and CISA KEV but is not endorsed or certified by these entities. CVE is a registred trademark of the MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. CWE is a registred trademark of the MITRE Corporation and the authoritative source of CWE content is MITRE's CWE web site.
© 2025 Under My Watch. All Rights Reserved.