An issue exists in SoftIron HyperCloud where drive caddy removal and reinsertion without a reboot may erroneously cause the system to recognize the caddy as new media and wipe all data on the drives due to a missing synchronization flaw, which impacts data availability and integrity. This issue only impacts SoftIron HyperCloud "density" storage nodes running HyperCloud software versions 1.0 to before 2.0.3.
The product utilizes a shared resource in a concurrent manner but does not attempt to synchronize access to the resource.
The product utilizes multiple threads or processes to allow temporary access to a shared resource that can only be exclusive to one process at a time, but it does not properly synchronize these actions, which might cause simultaneous accesses of this resource by multiple threads or processes.
Link | Tags |
---|---|
https://advisories.softiron.cloud | release notes |