CVE-2024-39562

Junos OS Evolved: A high rate of SSH connections causes a Denial of Service

Description

A Missing Release of Resource after Effective Lifetime vulnerability the xinetd process, responsible for spawning SSH daemon (sshd) instances, of Juniper Networks Junos OS Evolved allows an unauthenticated network-based attacker to cause a Denial of Service (DoS) by blocking SSH access for legitimate users. Continued receipt of these connections will create a sustained Denial of Service (DoS) condition. The issue is triggered when a high rate of concurrent SSH requests are received and terminated in a specific way, causing xinetd to crash, and leaving defunct sshd processes. Successful exploitation of this vulnerability blocks both SSH access as well as services which rely upon SSH, such as SFTP, and Netconf over SSH. Once the system is in this state, legitimate users will be unable to SSH to the device until service is manually restored.  See WORKAROUND section below. Administrators can monitor an increase in defunct sshd processes by utilizing the CLI command:   > show system processes | match sshd   root   25219 30901 0 Jul16 ?       00:00:00 [sshd] <defunct> This issue affects Juniper Networks Junos OS Evolved: * All versions prior to 21.4R3-S7-EVO * 22.3-EVO versions prior to 22.3R2-S2-EVO, 22.3R3-S2-EVO; * 22.4-EVO versions prior to 22.4R3-EVO; * 23.2-EVO versions prior to 23.2R2-EVO. This issue does not affect Juniper Networks Junos OS Evolved 22.1-EVO nor 22.2-EVO.

Remediation

Solution:

  • The following software releases have been updated to resolve this specific issue: Junos OS Evolved 21.4R3-S7-EVO, 22.2R1-EVO, 22.3R2-S2-EVO, 22.3R3-S2-EVO, 22.4R3-EVO, 23.2R2-EVO, 23.4R1-EVO, and all subsequent releases.

Workaround:

  • There are no known workarounds for this issue.

Category

8.7
CVSS
Severity: High
CVSS 4.0 •
CVSS 3.1 •
EPSS 0.29%
Vendor Advisory juniper.net Vendor Advisory first.org
Affected: Juniper Networks Junos OS Evolved
Published at:
Updated at:

References

Frequently Asked Questions

What is the severity of CVE-2024-39562?
CVE-2024-39562 has been scored as a high severity vulnerability.
How to fix CVE-2024-39562?
To fix CVE-2024-39562: The following software releases have been updated to resolve this specific issue: Junos OS Evolved 21.4R3-S7-EVO, 22.2R1-EVO, 22.3R2-S2-EVO, 22.3R3-S2-EVO, 22.4R3-EVO, 23.2R2-EVO, 23.4R1-EVO, and all subsequent releases.
Is CVE-2024-39562 being actively exploited in the wild?
As for now, there are no information to confirm that CVE-2024-39562 is being actively exploited. According to its EPSS score, there is a ~0% probability that this vulnerability will be exploited by malicious actors in the next 30 days.
What software or system is affected by CVE-2024-39562?
CVE-2024-39562 affects Juniper Networks Junos OS Evolved.
This platform uses data from the NIST NVD, MITRE CVE, MITRE CWE, First.org and CISA KEV but is not endorsed or certified by these entities. CVE is a registred trademark of the MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. CWE is a registred trademark of the MITRE Corporation and the authoritative source of CWE content is MITRE's CWE web site.