CVE-2024-43648

Authenticated command injection via .exe parameter

Description

Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H).  A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y).

Category

9.3
CVSS
Severity: Critical
CVSS 4.0 •
CVSS 3.1 •
EPSS 1.56% Top 20%
Third-Party Advisory divd.nl Third-Party Advisory divd.nl
Affected: Iocharger Iocharger firmware for AC models
Published at:
Updated at:

References

Frequently Asked Questions

What is the severity of CVE-2024-43648?
CVE-2024-43648 has been scored as a critical severity vulnerability.
How to fix CVE-2024-43648?
To fix CVE-2024-43648, make sure you are using an up-to-date version of the affected component(s) by checking the vendor release notes. As for now, there are no other specific guidelines available.
Is CVE-2024-43648 being actively exploited in the wild?
It is possible that CVE-2024-43648 is being exploited or will be exploited in a near future based on public information. According to its EPSS score, there is a ~2% probability that this vulnerability will be exploited by malicious actors in the next 30 days.
What software or system is affected by CVE-2024-43648?
CVE-2024-43648 affects Iocharger Iocharger firmware for AC models.
This platform uses data from the NIST NVD, MITRE CVE, MITRE CWE, First.org and CISA KEV but is not endorsed or certified by these entities. CVE is a registred trademark of the MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. CWE is a registred trademark of the MITRE Corporation and the authoritative source of CWE content is MITRE's CWE web site.
© 2025 Under My Watch. All Rights Reserved.