CVE-2024-43649

Authenticated command injection via .exe parameter

Description

Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).

Category

9.3
CVSS
Severity: Critical
CVSS 4.0 •
CVSS 3.1 •
EPSS 0.63%
Third-Party Advisory divd.nl Third-Party Advisory divd.nl
Affected: Iocharger Iocharger firmware for AC models
Published at:
Updated at:

References

Frequently Asked Questions

What is the severity of CVE-2024-43649?
CVE-2024-43649 has been scored as a critical severity vulnerability.
How to fix CVE-2024-43649?
To fix CVE-2024-43649, make sure you are using an up-to-date version of the affected component(s) by checking the vendor release notes. As for now, there are no other specific guidelines available.
Is CVE-2024-43649 being actively exploited in the wild?
As for now, there are no information to confirm that CVE-2024-43649 is being actively exploited. According to its EPSS score, there is a ~1% probability that this vulnerability will be exploited by malicious actors in the next 30 days.
What software or system is affected by CVE-2024-43649?
CVE-2024-43649 affects Iocharger Iocharger firmware for AC models.
This platform uses data from the NIST NVD, MITRE CVE, MITRE CWE, First.org and CISA KEV but is not endorsed or certified by these entities. CVE is a registred trademark of the MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. CWE is a registred trademark of the MITRE Corporation and the authoritative source of CWE content is MITRE's CWE web site.