CVE-2024-43662

Authenticated arbitrary file upload to /tmp/ and /tmp/upload/

Description

The <redacted>.exe or <redacted>.exe CGI binary can be used to upload arbitrary files to /tmp/upload/ or /tmp/ respectively as any user, although the user interface for uploading files is only shown to the iocadmin user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – An attacker will need to have knowledge of this CGI binary, e.g. by finding it in firmware. Furthermore, the attacker will need a (low privilege) account to gain access to the <redacted>.exe or <redacted>.exe CGI binary and upload the file, or convince a user with such access to upload it. Impact: Low – The attacker can upload arbitrary files to /tmp/upload/ or /tmp/. However, the attacker is unable to access or use these files without other vulnerabilities. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). Artitrary files can be uploaded, be these files will not be in a location where they can influence confidentiality or availability and have a minimal impact on device integrity (VC:N/VI:L/VA:N). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, we do not expect this vulnerability to have a safety impact. The attack can be automated (AU:Y).

Category

5.3
CVSS
Severity: Medium
CVSS 4.0 •
EPSS 0.11%
Third-Party Advisory divd.nl Third-Party Advisory divd.nl
Affected: Iocharger Iocharger firmware for AC models
Published at:
Updated at:

References

Frequently Asked Questions

What is the severity of CVE-2024-43662?
CVE-2024-43662 has been scored as a medium severity vulnerability.
How to fix CVE-2024-43662?
To fix CVE-2024-43662, make sure you are using an up-to-date version of the affected component(s) by checking the vendor release notes. As for now, there are no other specific guidelines available.
Is CVE-2024-43662 being actively exploited in the wild?
As for now, there are no information to confirm that CVE-2024-43662 is being actively exploited. According to its EPSS score, there is a ~0% probability that this vulnerability will be exploited by malicious actors in the next 30 days.
What software or system is affected by CVE-2024-43662?
CVE-2024-43662 affects Iocharger Iocharger firmware for AC models.
This platform uses data from the NIST NVD, MITRE CVE, MITRE CWE, First.org and CISA KEV but is not endorsed or certified by these entities. CVE is a registred trademark of the MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. CWE is a registred trademark of the MITRE Corporation and the authoritative source of CWE content is MITRE's CWE web site.
© 2025 Under My Watch. All Rights Reserved.