CVE-2025-30651

Junos OS and Junos OS Evolved: Receipt of a specific ICMPv6 packet causes a memory overrun leading to an rpd crash

Description

A Buffer Access with Incorrect Length Value vulnerability in the routing protocol daemon (rpd) of Juniper Networks Junos OS and Junos OS Evolved allows an unauthenticated, network-based attacker to cause a Denial of Service (DoS). When an attacker sends a specific ICMPv6 packet to an interface with "protocols router-advertisement" configured, rpd crashes and restarts. Continued receipt of this packet will cause a sustained DoS condition.  This issue only affects systems configured with IPv6. This issue affects Junos OS:  * All versions before 21.2R3-S9,  * from 21.4 before 21.4R3-S10, * from 22.2 before 22.2R3-S6, * from 22.4 before 22.4R3-S4, * from 23.2 before 23.2R2-S2, * from 23.4 before 23.4R2; and Junos OS Evolved: * All versions before 21.2R3-S9-EVO, * from 21.4-EVO before 21.4R3-S10-EVO, * from 22.2-EVO before 22.2R3-S6-EVO, * from 22.4-EVO before 22.4R3-S4-EVO, * from 23.2-EVO before 23.2R2-S2-EVO, * from 23.4-EVO before 23.4R2-EVO.

Remediation

Solution:

  • The following software releases have been updated to resolve this specific issue:  Junos OS: 21.2R3-S9, 21.4R3-S10, 22.2R3-S6, 22.4R3-S4, 23.2R2-S2, 23.4R2, 24.2R1, and all subsequent releases. Junos OS Evolved: 21.2R3-S9-EVO, 21.4R3-S10-EVO, 22.2R3-S6-EVO, 22.4R3-S4-EVO, 23.2R2-S2-EVO, 23.4R2-EVO, 24.2R1-EVO, and all subsequent releases.

Workaround:

  • There are no known workarounds for this issue. A firewall filter can be implemented to restrict ICMPv6 traffic.

Category

8.7
CVSS
Severity: High
CVSS 4.0 •
CVSS 3.1 •
EPSS 0.06%
Vendor Advisory juniper.net
Affected: Juniper Networks Junos OS
Affected: Juniper Networks Junos OS Evolved
Published at:
Updated at:

References

Frequently Asked Questions

What is the severity of CVE-2025-30651?
CVE-2025-30651 has been scored as a high severity vulnerability.
How to fix CVE-2025-30651?
To fix CVE-2025-30651: The following software releases have been updated to resolve this specific issue:  Junos OS: 21.2R3-S9, 21.4R3-S10, 22.2R3-S6, 22.4R3-S4, 23.2R2-S2, 23.4R2, 24.2R1, and all subsequent releases. Junos OS Evolved: 21.2R3-S9-EVO, 21.4R3-S10-EVO, 22.2R3-S6-EVO, 22.4R3-S4-EVO, 23.2R2-S2-EVO, 23.4R2-EVO, 24.2R1-EVO, and all subsequent releases.
Is CVE-2025-30651 being actively exploited in the wild?
As for now, there are no information to confirm that CVE-2025-30651 is being actively exploited. According to its EPSS score, there is a ~0% probability that this vulnerability will be exploited by malicious actors in the next 30 days.
What software or system is affected by CVE-2025-30651?
CVE-2025-30651 affects Juniper Networks Junos OS, Juniper Networks Junos OS Evolved.
This platform uses data from the NIST NVD, MITRE CVE, MITRE CWE, First.org and CISA KEV but is not endorsed or certified by these entities. CVE is a registred trademark of the MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. CWE is a registred trademark of the MITRE Corporation and the authoritative source of CWE content is MITRE's CWE web site.