CVE-2025-3259

Public Exploit
Tenda RX3 SetOnlineDevName formSetDeviceName stack-based overflow

Description

A vulnerability, which was classified as critical, has been found in Tenda RX3 16.03.13.11. This issue affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Categories

8.7
CVSS
Severity: High
CVSS 4.0 •
CVSS 3.1 •
CVSS 2.0 •
EPSS 0.13%
Third-Party Advisory vuldb.com Third-Party Advisory notion.site Third-Party Advisory vuldb.com Third-Party Advisory vuldb.com Third-Party Advisory com.cn Third-Party Advisory notion.site
Affected: Tenda RX3
Published at:
Updated at:

References

Link Tags
https://vuldb.com/?id.303329 third party advisory vdb entry technical description
https://vuldb.com/?ctiid.303329 signature third party advisory vdb entry permissions required
https://vuldb.com/?submit.549199 third party advisory vdb entry
https://sixth-action-50e.notion.site/Tenda-RX3-Buffer-Overflow-1c9f6468377380a2977cd6c3a81f453c?pvs=4 third party advisory exploit
https://www.tenda.com.cn/ third party advisory product vdb entry
https://sixth-action-50e.notion.site/Tenda-RX3-Buffer-Overflow-1c9f6468377380a2977cd6c3a81f453c exploit third party advisory

Frequently Asked Questions

What is the severity of CVE-2025-3259?
CVE-2025-3259 has been scored as a high severity vulnerability.
How to fix CVE-2025-3259?
To fix CVE-2025-3259, make sure you are using an up-to-date version of the affected component(s) by checking the vendor release notes. As for now, there are no other specific guidelines available.
Is CVE-2025-3259 being actively exploited in the wild?
It is possible that CVE-2025-3259 is being exploited or will be exploited in a near future based on public information. According to its EPSS score, there is a ~0% probability that this vulnerability will be exploited by malicious actors in the next 30 days.
What software or system is affected by CVE-2025-3259?
CVE-2025-3259 affects Tenda RX3.
This platform uses data from the NIST NVD, MITRE CVE, MITRE CWE, First.org and CISA KEV but is not endorsed or certified by these entities. CVE is a registred trademark of the MITRE Corporation and the authoritative source of CVE content is MITRE's CVE web site. CWE is a registred trademark of the MITRE Corporation and the authoritative source of CWE content is MITRE's CWE web site.